Analyzer solutions
SICK’s analyzer solutions provide forward-thinking concepts for measuring tasks in the fields of emission and process measurement technology. Typical fields of application include emission and process measurements in power plants, waste incineration plants, cement plants, and the chemical industry.

SICK’s CEMS solutions are analyzer solutions that have been specifically designed for measuring emissions at power plants, industrial facilities, or on ships. CEMS solutions can be used to measure pollutants and reference quantities and to perform data processing on the results in accordance with the relevant national or international legislation.

MCS200HW
- Measurement of up to 10 IR components plus O2 and TOC
- Hot/wet extractive measurement technology
- Wear-free gas distribution through ejector pumps
- Reference point monitoring with internal calibration cells
- Certified digital Modbus® interface
- Web server for platform-independent device control
- Use of dry test gases for HCl and NH3

MARSIC280
- Rugged design and high level of measurement accuracy
- Type-approved by several classification organizations in accordance with MARPOL Annex VI and IMO MEPC
- Optimized for SO2 and CO2 measurement downstream of the scrubber
- Use of field-tested MARSIC300 components

GHG-Control
- In-situ solution for measuring CO2 and N2O emissions
- Direct measurement even with changing fuels and mixed fuels
- Measurement without converting from the dry to damp status
- Transfer of the greenhouse gas loads directly to the control unit

MCS100FT
- Lowest approved HF measuring range: 0 … 3 mg/m³
- Automatic spectrum adjustment via AutoVAL for reliable measuring values
- Operation via touchscreen
- Sample gas transport by an ejector without moving parts
- Approved according to EN 15267
- Remote control and diagnosis via software SOPAS ET
- Automatic adjustment of analyzer
- Automatic backflushing and filter cleaning of sampling unit

MARSIC300
- Rugged design and high level of measurement accuracy
- Type-approved by well-known classification organizations in accordance with MARPOL Annex VI and IMO MEPC
- Measuring ranges adapted to low and high concentrations of SO2 and NOx
- Up to 7 measuring components at the same time: SO2, CO2, CO, NO, NO2, NH3, H2O

MEAC
- Evaluations according to 1, 2, 13, 17, 27, 30, 31 BImSchV and TA Luft
- Analog and digital data collection saved at 5 s/1 min intervals with auto-backup
- Distributed visualization, operation in the network and automatic e-mail alarms
- Flexible data presentation also in process images
- Analog and digital data to the customer system at 5 s/1 min intervals
- Recording of QAL3 cycles

MARSIC200
- Rugged design and high level of measurement accuracy
- Type-approved by several classification organizations in accordance with MARPOL Annex VI and IMO MEPC
- Measuring ranges adapted to low and high concentrations of SO2 and NOx
- Up to 5 measuring components at the same time: SO2, CO2, NO, NO2 and O2

MEAC300
- Bus-capable data acquisition from measuring devices and plants
- Evaluation conforming to the Industrial Emissions Directive, EN 14181 QAL2, and optionally QAL3 (CUSUM)
- Secure storage with automated backup
- Ergonomic display for constant monitoring of evaluation rules and device statuses
- Fast data transmission to the plant control in a 5 s cycle

Combi probe CP100
- No need for mechanical adjustment
- Self-testing with the automatic control cycle
- Simple configuration and operation with easy-to-use software
- For gas temperatures up to 200 °C
- For funnels with an internal diameter of 0.7 m and above

Industrial processes and systems vary widely depending on the nature of the production method involved. In turn, this means that the associated measurement tasks and process-related requirements differ a great deal as well. SICK provides solutions and complete systems based on its extensive experience within the field of process measurement technology.
MCS300P HW
- Simultaneous measurement of up to 6 components plus O2
- Measurement gas flow monitoring and measurement gas pressure detection
- Temperature of the system components up to 200 °C
- Automated sample point switching for up to 3 sample points (optional)
- Automated adjustment to the zero and reference point
- Integrated adjustment of the device without test gas (optional)
- Extended operation via PC and SOPAS ET software
- Flexible I/O module system